Super Purchasing for Skalar Bod Analyzer - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Good quality comes to start with; service is foremost; organization is cooperation" is our enterprise philosophy which is regularly observed and pursued by our firm for Bod Analyzer 12 Tests , Aquarium Water Tests , Harga Alat Turbidity Meter , Welcome friends from all over the world come to visit, guide and negotiate.
Super Purchasing for Skalar Bod Analyzer - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua Detail:

Product Introduction

According to the national standard (HJ 505-2009) Water quality-Determination of biochemical oxygen demand after five days(BOD5) for dilution and seeding method, 12 samples once, safe and reliable mercury-free differential pressure sensing method (breathing method) is used to measure BOD in water, which completely simulates the biodegradation process of organic matter in nature. R&D process design and manufacturing, industry-leading function settings, fully intelligent design, unattended measurement process, automatic recording of data, completely saying goodbye to mercury poisoning caused by mercury leakage, is a BOD specially tailored for water quality analysis laboratories Professional analytical instruments.

Features

1) The method is safe and reliable: the mercury-free manometric method is adopted, no mercury pollution, and the data is accurate and reliable;

2) The measurement is independent and flexible: the test individual is independent, and the start time of a single sample can be determined at any time;

3) Color LCD screen: each test cap has a color LCD screen, which independently displays the test time, measurement results, sampling amount, etc.;

4) Control system: The microprocessor control system is used to automatically complete the measurement process without special care;

5) Wide range and optional: BOD value of (0~4000) mg/L can be determined without dilution;

6) Concentration direct reading: 1-12 samples can be measured without conversion, and the BOD concentration value can be directly displayed;

7) The mobility of the instrument is enhanced: each test cap has a built-in battery, and short-term power-off has no effect on the test, reducing the dependence on electric energy;

8) Large batch size: up to 12 samples can be measured at one time;

9) Easy to operate: only need a simple button to complete the setting, and the water sample can be bottled according to the volume set by the range to complete the test;

10) Automatic data recording: you can view the current experimental data at any time, as well as the five-day biochemical oxygen demand historical data;

11) Complete experimental accessories: equipped with all the reagents and accessories required for the experiment, which is convenient for accurate and fast sampling.

Specification

Product Name

Biochemical oxygen demand (BOD5 meter)

Model

LH-BOD1201

Accuracy

≤±5%

Range

(0~4000)mg/L

Minimum value

2mg/L

Volume

580mL

Repeatability

≤±5%

Samples

12 samples once

Data storage

5 and 7days

Period

5 and 7 optional

Dimension

(390×294×95)mm

Weight

6.5Kg

Test temperature

(20±1)℃

Environment humidity

≤85%RH (no condensation)

Supply

AC(100-240V)±10%/(50-60)Hz

Power

60W


Product detail pictures:

Super Purchasing for Skalar Bod Analyzer - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures

Super Purchasing for Skalar Bod Analyzer - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures

Super Purchasing for Skalar Bod Analyzer - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures

Super Purchasing for Skalar Bod Analyzer - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures

Super Purchasing for Skalar Bod Analyzer - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures

Super Purchasing for Skalar Bod Analyzer - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures

Super Purchasing for Skalar Bod Analyzer - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures


Related Product Guide:

abide by the contract", conforms to the market requirement, joins in the market competition by its high quality as well as provides more comprehensive and excellent service for clients to let them become big winner. The pursue of the company, is the clients' satisfaction for Super Purchasing for Skalar Bod Analyzer - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua , The product will supply to all over the world, such as: Belize, Sydney, Gambia, We welcome customers from all over the world come to discuss business. We supply high quality solutions, reasonable prices and good services. We hope to sincerely build business relationships with customers from at home and abroad, jointly striving for a resplendent tomorrow.
  • We always believe that the details decides the company's product quality, in this respect, the company conform our requirements and the goods are meet our expectations.
    5 Stars By Eden from Karachi - 2018.05.22 12:13
    This is a very professional and honest Chinese supplier, from now on we fell in love with the Chinese manufacturing.
    5 Stars By Ruth from Bangkok - 2018.12.11 14:13
    Write your message here and send it to us