Our primary goal is to offer our clients a serious and responsible business relationship, providing personalized attention to all of them for Water Quality Cod , Water Testing Equipment , Chemical Oxygen Demand Vial , Therefore, we can meet different inquiries from different clients. Please find our website to check more information from our products.
Special Design for Bod₅ Testing - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua Detail:

Product Introduction

According to the national standard (HJ 505-2009) Water quality-Determination of biochemical oxygen demand after five days(BOD5) for dilution and seeding method, 12 samples once, safe and reliable mercury-free differential pressure sensing method (breathing method) is used to measure BOD in water, which completely simulates the biodegradation process of organic matter in nature. R&D process design and manufacturing, industry-leading function settings, fully intelligent design, unattended measurement process, automatic recording of data, completely saying goodbye to mercury poisoning caused by mercury leakage, is a BOD specially tailored for water quality analysis laboratories Professional analytical instruments.

Features

1) The method is safe and reliable: the mercury-free manometric method is adopted, no mercury pollution, and the data is accurate and reliable;

2) The measurement is independent and flexible: the test individual is independent, and the start time of a single sample can be determined at any time;

3) Color LCD screen: each test cap has a color LCD screen, which independently displays the test time, measurement results, sampling amount, etc.;

4) Control system: The microprocessor control system is used to automatically complete the measurement process without special care;

5) Wide range and optional: BOD value of (0~4000) mg/L can be determined without dilution;

6) Concentration direct reading: 1-12 samples can be measured without conversion, and the BOD concentration value can be directly displayed;

7) The mobility of the instrument is enhanced: each test cap has a built-in battery, and short-term power-off has no effect on the test, reducing the dependence on electric energy;

8) Large batch size: up to 12 samples can be measured at one time;

9) Easy to operate: only need a simple button to complete the setting, and the water sample can be bottled according to the volume set by the range to complete the test;

10) Automatic data recording: you can view the current experimental data at any time, as well as the five-day biochemical oxygen demand historical data;

11) Complete experimental accessories: equipped with all the reagents and accessories required for the experiment, which is convenient for accurate and fast sampling.

Specification

Product Name

Biochemical oxygen demand (BOD5 meter)

Model

LH-BOD1201

Accuracy

≤±5%

Range

(0~4000)mg/L

Minimum value

2mg/L

Volume

580mL

Repeatability

≤±5%

Samples

12 samples once

Data storage

5 and 7days

Period

5 and 7 optional

Dimension

(390×294×95)mm

Weight

6.5Kg

Test temperature

(20±1)℃

Environment humidity

≤85%RH (no condensation)

Supply

AC(100-240V)±10%/(50-60)Hz

Power

60W


Product detail pictures:

Special Design for Bod₅ Testing - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures

Special Design for Bod₅ Testing - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures

Special Design for Bod₅ Testing - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures

Special Design for Bod₅ Testing - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures

Special Design for Bod₅ Testing - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures

Special Design for Bod₅ Testing - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures

Special Design for Bod₅ Testing - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures


Related Product Guide:

We have been experienced manufacturer. Wining the majority of your crucial certifications of its market for Special Design for Bod₅ Testing - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua , The product will supply to all over the world, such as: Kuwait, Barcelona, Houston, With a team of experienced and knowledgeable personnel, our market covers South America, the USA, the Mid East, and North Africa. Many customers have become our friends after good cooperation with us. If you have the requirement for any of our goods, make sure you contact us now. We're looking forward to hearing from you soon.
  • Adhering to the business principle of mutual benefits, we have a happy and successful transaction, we think we will be the best business partner.
    5 Stars By Constance from Peru - 2017.03.28 12:22
    This company can be well to meet our needs on product quantity and delivery time, so we always choose them when we have procurement requirements.
    5 Stars By Freda from Austria - 2017.05.02 18:28
    Write your message here and send it to us