We retain bettering and perfecting our merchandise and service. At the same time, we do the job actively to do research and improvement for Lab Use Liquid Digestion System , Types Of Turbidity Meter , Total Suspended Solids Analyzer , If you are looking for Good Quality at a good price and timely delivery. Do contact us.
Manufacturer of Cod Analyzer Price - Intelligent COD Rapid Tester 5B-3C(V8) – Lianhua Detail:

Product Introduction

It is designed and manufactured according to “Water quality-Determination of the chemical oxygen demand-Fast digestion-Spectrophotometric method”. It can test COD value in water in 20 minutes.

Functional characteristics

1. Quick and accurate test of chemical oxygen demand (COD) in surface water, reclaimed water, municipal wastewater and industrial wastewater.
2. The independent dual optical system has the advantages of direct reading, high accuracy, long service life and more stable.
3. The 3.5 inch color LCD screen, humanized operation hint, simple to use.
4. Self-calibration function of the instrument can be calculated and stored according to the standard sample, without manual production of curves.
5. Large and small font display mode is free to switch, showing clearer data and more detailed parameters.
6. It can transmit the current data and all stored historical data to the computer, and support USB transmission and infrared wireless transmission. (selecting)
7. Support both colorimetric cuvette and colorimetric tubes.
8. The printer can print current data and all stored historical data.
9. Equipped with professional consumables reagents, the working procedures are greatly reduced, the measurement is simpler and the results are more accurate.
10. The instrument adopts the self-designed non-metal case. The machine is beautiful and generous.
11. Support twelve thousand historical data storage (date, time, parameters, measurement results).

Technical Parameters

Item

COD high range

COD low range

Range

20-10000mg/L(subsection)

2-150mg/L(subsection)

Accuracy

COD<50mg/L, accuracy≤±5%
COD>50mg/L, accuracy≤±3%

≤±5%

limits of detection

0.1mg/L

0.1mg/L

Determination time

20min

20min

Repeatability

≤±5%

Lamp life

100 thousands hours

Optical stability

≤±0.005A/20min

Anti-chlorine interference

<1000mg/L no influence ;<100000mg/L Optional

Colorimetric method

Cuvette/Tube

Data storage

12000

Curve data

180

Display mode

LCD(Resolution 320*240)

Communication interface

USB /Infar-red (optional)

Power supply

220V

Advantage

● Results in 20 minutes
● Built-in printer
● Dual wavelength (420nm, 610nm), detect high and low concentration samples
● Concentration is displayed directly without calculation
● Less reagent consumption, reducing pollution
● Simple operation, no professional use
● Can provide powder reagents, convenient shipping, low price
● Can choose 9/12/16/25 position digester

Application

Sewage treatment plants, monitoring bureaus, environmental treatment companies, chemical plants, pharmaceutical plants, textile plants, university laboratories, food and beverage plants, etc.


Product detail pictures:

Manufacturer of Cod Analyzer Price - Intelligent COD Rapid Tester  5B-3C(V8) – Lianhua detail pictures

Manufacturer of Cod Analyzer Price - Intelligent COD Rapid Tester  5B-3C(V8) – Lianhua detail pictures

Manufacturer of Cod Analyzer Price - Intelligent COD Rapid Tester  5B-3C(V8) – Lianhua detail pictures

Manufacturer of Cod Analyzer Price - Intelligent COD Rapid Tester  5B-3C(V8) – Lianhua detail pictures

Manufacturer of Cod Analyzer Price - Intelligent COD Rapid Tester  5B-3C(V8) – Lianhua detail pictures

Manufacturer of Cod Analyzer Price - Intelligent COD Rapid Tester  5B-3C(V8) – Lianhua detail pictures

Manufacturer of Cod Analyzer Price - Intelligent COD Rapid Tester  5B-3C(V8) – Lianhua detail pictures


Related Product Guide:

Our business has been focusing on brand strategy. Customers' pleasure is our best advertising. We also offer OEM company for Manufacturer of Cod Analyzer Price - Intelligent COD Rapid Tester 5B-3C(V8) – Lianhua , The product will supply to all over the world, such as: Saudi Arabia, Liverpool, Zurich, To win customers' confidence, Best Source has set up a strong sales and after-sales team to provide the best product and service. Best Source abides by the idea of "Grow with customer" and philosophy of "Customer-oriented" to achieve cooperation of mutual trust and benefit. Best Source will always stand ready to cooperate with you. Let's grow together!
  • The quality of the products is very good, especially in the details, can be seen that the company work actively to satisfy customer's interest, a nice supplier.
    5 Stars By Nicci Hackner from Surabaya - 2018.09.12 17:18
    This is the first business after our company establish, products and services are very satisfying, we have a good start, we hope to cooperate continuous in the future!
    5 Stars By Maria from UK - 2017.06.16 18:23
    Write your message here and send it to us