Gaining purchaser gratification is our company's aim eternally. We're going to make great initiatives to create new and top-quality products, satisfy your exclusive prerequisites and supply you with pre-sale, on-sale and after-sale solutions for Field Turbidity Meter , Chemical Instrument , Laboratory Digester , Our tenet is "Reasonable prices, efficient production time and best service" We hope to cooperate with more customers for mutual development and benefits.
Best quality Lab Bod Mecine - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua Detail:

Product Introduction

According to the national standard (HJ 505-2009) Water quality-Determination of biochemical oxygen demand after five days(BOD5) for dilution and seeding method, 12 samples once, safe and reliable mercury-free differential pressure sensing method (breathing method) is used to measure BOD in water, which completely simulates the biodegradation process of organic matter in nature. R&D process design and manufacturing, industry-leading function settings, fully intelligent design, unattended measurement process, automatic recording of data, completely saying goodbye to mercury poisoning caused by mercury leakage, is a BOD specially tailored for water quality analysis laboratories Professional analytical instruments.

Features

1) The method is safe and reliable: the mercury-free manometric method is adopted, no mercury pollution, and the data is accurate and reliable;

2) The measurement is independent and flexible: the test individual is independent, and the start time of a single sample can be determined at any time;

3) Color LCD screen: each test cap has a color LCD screen, which independently displays the test time, measurement results, sampling amount, etc.;

4) Control system: The microprocessor control system is used to automatically complete the measurement process without special care;

5) Wide range and optional: BOD value of (0~4000) mg/L can be determined without dilution;

6) Concentration direct reading: 1-12 samples can be measured without conversion, and the BOD concentration value can be directly displayed;

7) The mobility of the instrument is enhanced: each test cap has a built-in battery, and short-term power-off has no effect on the test, reducing the dependence on electric energy;

8) Large batch size: up to 12 samples can be measured at one time;

9) Easy to operate: only need a simple button to complete the setting, and the water sample can be bottled according to the volume set by the range to complete the test;

10) Automatic data recording: you can view the current experimental data at any time, as well as the five-day biochemical oxygen demand historical data;

11) Complete experimental accessories: equipped with all the reagents and accessories required for the experiment, which is convenient for accurate and fast sampling.

Specification

Product Name

Biochemical oxygen demand (BOD5 meter)

Model

LH-BOD1201

Accuracy

≤±5%

Range

(0~4000)mg/L

Minimum value

2mg/L

Volume

580mL

Repeatability

≤±5%

Samples

12 samples once

Data storage

5 and 7days

Period

5 and 7 optional

Dimension

(390×294×95)mm

Weight

6.5Kg

Test temperature

(20±1)℃

Environment humidity

≤85%RH (no condensation)

Supply

AC(100-240V)±10%/(50-60)Hz

Power

60W


Product detail pictures:

Best quality Lab Bod Mecine - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures

Best quality Lab Bod Mecine - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures

Best quality Lab Bod Mecine - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures

Best quality Lab Bod Mecine - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures

Best quality Lab Bod Mecine - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures

Best quality Lab Bod Mecine - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures

Best quality Lab Bod Mecine - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures


Related Product Guide:

We not only will try our best to offer excellent services to every customer, but also are ready to receive any suggestion offered by our customers for Best quality Lab Bod Mecine - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua , The product will supply to all over the world, such as: Namibia, Accra, Algeria, Providing the best products, the most perfect service with the most reasonable prices are our principles. We also welcome OEM and ODM orders.Dedicated to strict quality control and thoughtful customer service, we are always available to discuss your requirements and ensure full customer satisfaction. We sincerely welcome friends to come negotiate business and start cooperation.
  • We feel easy to cooperate with this company, the supplier is very responsible, thanks.There will be more in-depth cooperation.
    5 Stars By Lindsay from Bangladesh - 2018.06.30 17:29
    It is not easy to find such a professional and responsible provider in today's time. Hope that we can maintain long-term cooperation.
    5 Stars By Julia from Iran - 2017.09.16 13:44
    Write your message here and send it to us