We believe that prolonged expression partnership is really a result of top of the range, value added support, rich encounter and personal contact for Water Quality Testing Machine , Multi Parameter Meter , Measuring Sensors For Bod , Striving hard to attain continual success determined by high quality, reliability, integrity, and complete understanding of current market dynamics.
Best quality Lab Bod Mecine - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua Detail:

Product Introduction

According to the national standard (HJ 505-2009) Water quality-Determination of biochemical oxygen demand after five days(BOD5) for dilution and seeding method, 12 samples once, safe and reliable mercury-free differential pressure sensing method (breathing method) is used to measure BOD in water, which completely simulates the biodegradation process of organic matter in nature. R&D process design and manufacturing, industry-leading function settings, fully intelligent design, unattended measurement process, automatic recording of data, completely saying goodbye to mercury poisoning caused by mercury leakage, is a BOD specially tailored for water quality analysis laboratories Professional analytical instruments.

Features

1) The method is safe and reliable: the mercury-free manometric method is adopted, no mercury pollution, and the data is accurate and reliable;

2) The measurement is independent and flexible: the test individual is independent, and the start time of a single sample can be determined at any time;

3) Color LCD screen: each test cap has a color LCD screen, which independently displays the test time, measurement results, sampling amount, etc.;

4) Control system: The microprocessor control system is used to automatically complete the measurement process without special care;

5) Wide range and optional: BOD value of (0~4000) mg/L can be determined without dilution;

6) Concentration direct reading: 1-12 samples can be measured without conversion, and the BOD concentration value can be directly displayed;

7) The mobility of the instrument is enhanced: each test cap has a built-in battery, and short-term power-off has no effect on the test, reducing the dependence on electric energy;

8) Large batch size: up to 12 samples can be measured at one time;

9) Easy to operate: only need a simple button to complete the setting, and the water sample can be bottled according to the volume set by the range to complete the test;

10) Automatic data recording: you can view the current experimental data at any time, as well as the five-day biochemical oxygen demand historical data;

11) Complete experimental accessories: equipped with all the reagents and accessories required for the experiment, which is convenient for accurate and fast sampling.

Specification

Product Name

Biochemical oxygen demand (BOD5 meter)

Model

LH-BOD1201

Accuracy

≤±5%

Range

(0~4000)mg/L

Minimum value

2mg/L

Volume

580mL

Repeatability

≤±5%

Samples

12 samples once

Data storage

5 and 7days

Period

5 and 7 optional

Dimension

(390×294×95)mm

Weight

6.5Kg

Test temperature

(20±1)℃

Environment humidity

≤85%RH (no condensation)

Supply

AC(100-240V)±10%/(50-60)Hz

Power

60W


Product detail pictures:

Best quality Lab Bod Mecine - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures

Best quality Lab Bod Mecine - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures

Best quality Lab Bod Mecine - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures

Best quality Lab Bod Mecine - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures

Best quality Lab Bod Mecine - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures

Best quality Lab Bod Mecine - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures

Best quality Lab Bod Mecine - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures


Related Product Guide:

Along with the "Client-Oriented" small business philosophy, a rigorous high-quality handle system, highly developed producing machines and a powerful R&D group, we always supply high-quality products and solutions, fantastic services and aggressive costs for Best quality Lab Bod Mecine - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua , The product will supply to all over the world, such as: Nepal, Toronto, Belgium, Satisfaction and good credit to every customer is our priority. We focus on every detail of order processing for customers till they have received safe and sound solutions with good logistics service and economical cost. Depending on this, our solutions are sold very well in the countries in Africa, the Mid-East and Southeast Asia.
  • The factory has advanced equipment, experienced staffs and good management level, so product quality had assurance, this cooperation is very relaxed and happy!
    5 Stars By Brook from luzern - 2018.04.25 16:46
    This company has a lot of ready-made options to choose and also could custom new program according to our demand, which is very nice to meet our needs.
    5 Stars By Pag from Paris - 2018.09.29 13:24
    Write your message here and send it to us